APPROVED DOCUMENT K

 0    58 Fiche    sim
скачать mp3 басу ойын өзіңді тексер
 
сұрақ жауап
approved
What is a approved Document?
оқуды бастаңыз
zatwierdzony
Building Regulations
оқуды бастаңыз
Przepisy budowlane
protection from impact
Protection from falling, collision and impact
оқуды бастаңыз
Ochrona przed uderzeniami
impact
The definition of impact is one thing crashing into or having an affect on another.
оқуды бастаңыз
wpływ / zderzenie
ladder
оқуды бастаңыз
drabina
loading bays
оқуды бастаңыз
strefa załadunku
Vehicle barriers
оқуды бастаңыз
Bariery pojazdów
glazing
оқуды бастаңыз
szyby
provisions
Additional provisions for glazing in buildings other than dwellings.
оқуды бастаңыз
Przepisy
dwellings
Additional provisions for glazing in buildings other than dwellings.
оқуды бастаңыз
mieszkaniowe
trapping by doors
trap.
оқуды бастаңыз
uwięzienie przez drzwi
pułapka
compliance with the law
оқуды бастаңыз
zgodność z prawem
workmanship
оқуды бастаңыз
jakość wykonania
Handrail
оқуды бастаңыз
Poręcz
helical stair
helical stair = spiral stair
оқуды бастаңыз
spiralny schody
noising
оқуды бастаңыз
nosek schodów
stair tread
оқуды бастаңыз
stopnica
pitch
оқуды бастаңыз
kąt nachylenia
rise
оқуды бастаңыз
wysokość stopnia
riser
оқуды бастаңыз
wysokość stopnia
landing
The width and length of every landing should be at least as great as the smallest width of the flight. (minimum 1 m)
оқуды бастаңыз
podest / spocznik
staircase
оқуды бастаңыз
klatka schodowa
stair enclosure
оқуды бастаңыз
klatka schodowa
flight of stairs
оқуды бастаңыз
bieg schodów
straight flight stairs
оқуды бастаңыз
Schody jednobiegowe proste
dog-legged stairs
оқуды бастаңыз
Schody dwubiegunowe proste
winding stairs
оқуды бастаңыз
kręte schody
cantiliver stairs
оқуды бастаңыз
schody wspornikowe
timber stairs
оқуды бастаңыз
Schody z drewna
going
going = tread
оқуды бастаңыз
stopnica
RISER in PRIVATE STAIRS
Rise maximum 220mm. RISE = 150mm- 220mm.
оқуды бастаңыз
wysokość stopnia
H = 150mm-220mm
GOING in PRIVATE STAIRS
GOING minimum 220mm. GOING = 220mm- 300mm.
оқуды бастаңыз
SZEROKOŚĆ STOPNIA
intended
Private: intended to be used for only one dwelling.
оқуды бастаңыз
przeznaczony
assembly
Institutional and assembly: Serving a place where many people gather.
оқуды бастаңыз
zgromadzenie
gather
Institutional and assembly: Serving a place where many people gather.
оқуды бастаңыз
zbierać
headroom
Minimum headroom= 2m.
оқуды бастаңыз
wysokość prześwitu
Institutional and assembly stairs
Maximum rise = 180mm. Minimum going 280.(If the area of a floor of the building is less than 100m2, the going may be reduced to 250mm.)
оқуды бастаңыз
Instytucjonalne i zbiorowe schody
Pitch
the maximum pitch for private stair is 42°.
оқуды бастаңыз
kąt nachylenia
gangway for seated spectators
The maximum pitch for gangways for seated spectators is 35°.
оқуды бастаңыз
Przejście na siedzących widzów
escalator
оқуды бастаңыз
schody ruchome
stair well
оқуды бастаңыз
dusza schodów
fire escape stairs
оқуды бастаңыз
schody ewakuacyjne
dividing flights
A stair in a public building which is wider than 1800mm should be divided into flights which are not wider than 1800mm.
оқуды бастаңыз
podzielenie biegu
length of flights
The number of risers in a flight should be limited to 16 if a stair serves an area used as a shop or for assembly purposes.
оқуды бастаңыз
długość biegu
lending next to doors
at least 400mm.
оқуды бастаңыз
spocznik obok drzwi
cupboard
at least 400mm.
оқуды бастаңыз
szafka nad spocznikiem
alternating tread stair
оқуды бастаңыз
zmienny stopień
walkways
оқуды бастаңыз
chodniki
Handrails for stairs
In all buildings hadrail height should be between 900mm and 1000mm measured to the top of the handrail from the pitch line or floor.
оқуды бастаңыз
Poręcze na schodach
guarding
Flights and landings shoul be guarded at the sides (in dewellings) when there is a drop of more than 600mm.
оқуды бастаңыз
osłona / ochrona
drop
оқуды бастаңыз
spadek
guarding
Single family dwellings:1. Stairs, landings, ramps, edges of internal floors. H= 900mm. 2. External balconies and edges of roof. H= 1100mm.
оқуды бастаңыз
osłona / ochrona
suitable handrails for common stairs
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
оқуды бастаңыз
odpowiednie porecze dla powszechnych schodów poręcze
formula
The normal relationship between the dimensions of the rise and going is that twice the rise plus the going (2R+G) should be between 550mm and 700mm.
оқуды бастаңыз
wzór
2R+G = 550mm -700mm
readily
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
оқуды бастаңыз
łatwo
Utility stair
оқуды бастаңыз
schody użyteczności publicznej
external stairs
For dwellings, for external tapered stairs that are part of the buildings, the going should be a minimum of 280mm.
оқуды бастаңыз
schody zewnętrzne
Width of STAIRS
minimum width of 900mm. Landings should be at least the width and length of the minimum width of the fight. For buildings other than dwellings, each landing should have an unobstructed length of at least 1,200m.
оқуды бастаңыз
Szerokość schodów